Series TX200 Transmitting Variable Area Flowmeter

GENERAL INFORMATION

The MPB Series TX200 Metal Tube VA Flowmeter has been designed to measure flow volumes of aggressive chemicals at higher-than-average pressures.
As standard supplied with 1/8” NPT female end connections.

 

Download Technical Bulletin which shows standard flow rates: Technical Bulletin

Download Installation Instructions: Installation Instructions

For further information please complete the form below, or contact us direct by telephone or e-mail.

Tel: +44 (0)1622 872401
Email: sales@mpbflowmeters.com

 

Description

SERIES TX200 METAL TUBE VARIABLE AREA FLOWMETER FEATURES

• FLOW METERING OF GASES AT PRESSURES UP TO 700 PSI AND TEMPERATURES TO 150°C
• PRECISE FLOWRATE CONTROL VIA AN INLET CONTROL VALVE
• 316 (A4) STAINLESS STEEL FLOW PARTS GIVES EXCELLENT CORROSION RESISTANCE
• ROBUST DESIGN
• VERTICAL CONNECTIONS
• NON-VALVED VERSION AVAILABLE
• COMPACT DESIGN
• VITON VALVE SEAL
• OPTIONAL ADJUSTABLE 4- 20 mA OUTPUT
• OPTIONAL ADJUSTABLE HIGH & LOW FLOW ALARM CONTACT OUTPUTS CONFIGURABLE AS NO OR NC

Enclosure: Aluminium
Standard Scale: 0-100% (Optional 10:1 calibrated)
Standard Seals: Viton
Metering Tube: 316 Stainless Steel
Float: 316 Stainless Steel
Weight: 1kg
Accuracy: +/- 5% FSD predicted
Maximum Working Pressure: up to 50 bar g
Maximum Working Temperature: 150°C (Viton)

Electrical Specifications:
4-20mA Features:
• Wide 6-36Vdc input voltage supply range
• 0.05mA output resolution
• Easy push button setup
• Optional NAMUR NE43 extended working range and diagnostics mode

Alarm Option:
• Separate 7.5-12Vdc input voltage supply required
• Individual upper and lower alarm relays and output connections
• Relay contact ratings: 48Vdc/0.1A ( 5 W max )
• Easy push button alarm level setting
• Relays configurable as NO or NC